An agent should set this object to an enterprise-specific registration identifier value, indicating the
specific equipment type in detail. The associated instance of entPhysicalClass indicates the
general type of hardware device.
If no vendor-specific registration identifier exists for this physical entity, or if the value is unknown
by this agent, then the value { 0, 0 } is returned.
Returns
Currently, NULL OID { 0, 0 } is returned.
entPhysicalContainedIn 1.3.6.1.2.1.47.1.1.1.1.4
The value of entPhysicalIndex for the physical entity that "contains" this physical entity. A value of
0 indicates this physical entity is not contained in any other physical entity. Note that the set of
containment relationships define a strict hierarchy; that is, recursion is not allowed.
In the event a physical entity is contained by more than one physical entity (for example,
double-wide modules), this object should identify the containing entity with the lowest value of
entPhysicalIndex.
Value 0 for chassis entry. All containers have ContainedIn set to 1. All FRUs are contained in their
respective slot container entries.
entPhysicalClass 1.3.6.1.2.1.47.1.1.1.1.5
An indication of the general hardware type of the physical entity.
An agent should set this object to the standard enumeration value that most accurately indicates
the general class of the physical entity, or the primary class if there is more than one.
If no appropriate standard registration identifier exists for this physical entity, then the value
other(1)
Brocade DCX directors can have the following hierarchy of physical objects:
Module: Eight entries for port blades, two entries for CPs, four entries for power supplies, and three
entries for fans.
Brocade 12000, 24000, and 48000 directors can have the following hierarchy of physical objects:
Brocade 3900 switches can have the following hierarchy of physical objects:
Fabric OS MIB Reference
53-1000602-01
is returned. If the value is unknown by this agent, then the value
-
Chassis: One entry (one row)
-
Container: One entry for each FRU slot (eight port blades, two CPs, four power supplies,
three fans)
-
Chassis: One entry (one row)
-
Container: One entry for each FRU slot (eight port blades, two CPs, four power supplies,
three fans)
-
Module: Eight entries for port blades, two entries for CPs, four entries for power supplies,
and three entries for fans.
-
Chassis: One entry (one row)
-
Container: One entry for each FRU slot (one switch blade, two power supplies, six fans)
-
Module: One entry for switch blade, up to two entries for power supplies, and up to six
entries for fans.
entPhysicalContainedIn 1.3.6.1.2.1.47.1.1.1.1.4
4
is returned.
unknown(2)
103