Sign In
Upload
Manuals
Brands
HP Manuals
Software
StorageWorks 64 - SAN Director Switch
HP StorageWorks 64 - SAN Director Switch Manuals
Manuals and User Guides for HP StorageWorks 64 - SAN Director Switch. We have
3
HP StorageWorks 64 - SAN Director Switch manuals available for free PDF download: Planning Manual, Cli Reference Manual, User Manual
HP StorageWorks 64 - SAN Director Switch Planning Manual (174 pages)
StorageWorks SAN high availability
Brand:
HP
| Category:
Switch
| Size: 16.97 MB
Table of Contents
Table of Contents
3
About this Guide
9
Overview
10
Intended Audience
10
Related Documentation
10
Conventions
11
Document Conventions
11
Text Symbols
12
Equipment Symbols
12
Rack Stability
13
Getting Help
14
HP Technical Support
14
HP Storage Website
14
HP Authorized Reseller
14
Introduction to HP Fibre Channel Products
15
Product Overview
15
Rack-Mount HP Products
17
Directors
18
Director Performance
19
Director 2/64
21
Director 2/64 (Front View)
21
Director 2/64 (Rear View)
22
Director 2/140
23
Director 2/140 (Front View)
23
Director 2/140 (Rear View)
24
Edge Switches
25
Edge Switch Performance
25
Edge Switch 2/16
26
Edge Switch 2/16 (Front View)
26
Edge Switch 2/16 (Rear View)
27
Edge Switch 2/24
28
Edge Switch 2/24 (Front View)
28
Edge Switch 2/24 (Rear View)
29
Edge Switch 2/32
30
Edge Switch 2/32 (Front View)
30
Edge Switch 2/32 (Rear View)
31
Product Features
32
Connectivity Features
32
Security Features
33
Serviceability Features
34
Product Management
37
Product Management
38
Out-Of-Band Product Management
39
Inband Product Management
40
HAFM Server Description
41
HAFM Server
41
HAFM Server Specifications
42
Ethernet Hub
43
Remote User Workstations
43
HP Ethernet Hub
43
Product Firmware
44
Backup and Restore Features
45
Product Software
47
Management Services Application
47
Graphical User Interface
48
HAFM Application
48
Products View
49
Fabrics View
51
Fabrics View - Topology Tab
51
Fabrics View - Zone Set Tab
52
Product Manager Application
53
Hardware View
53
Embedded Web Server Interface
54
View Panel (Embedded Web Server Interface)
55
Command Line Interface
56
Planning Considerations for Fibre Channel Topologies
57
Fibre Channel Topologies
58
Planning for Point-To-Point Connectivity
59
Characteristics of Arbitrated Loop Operation
60
Shared Mode Versus Switched Mode
60
Shared Mode Operation
61
Public Versus Private Devices
62
Switched Mode Operation
62
Public Device Connectivity
63
Private Device Connectivity
64
Public Versus Private Loops
65
Public Loop Connectivity
65
Planning for Private Arbitrated Loop Connectivity
66
Private Loop Connectivity
66
Shared Mode Operation
67
Shared Mode Operation and Logical Equivalent
67
Device Private Arbitrated Loop
68
Switched Mode Operation
70
Switched Mode Operation and Logical Equivalent
70
Switched Mode Operation with Eight Independent Looplets
71
Planning for Fabric-Attached Loop Connectivity
73
Connecting a SAN to a Switched Fabric
73
Arbitrated Loop to Switched Fabric Connectivity
74
ISL Bandwidth Limitation
75
Server Consolidation
76
Tape Device Consolidation
77
Tape Drive Consolidation
77
Planning for Multi-Switch Fabric Support
78
Example Multi-Switch Fabric
78
Fabric Topology Limits
79
Factors to Consider When Implementing a Fabric Topology
80
ISL Transfer Rate Versus Fabric Port Availability (Two-Director Fabric)
82
Fabric Topologies
89
Cascaded Fabric
89
Cascaded Fabric
90
Ring Fabric
91
Mesh Fabric
92
Full Mesh Fabric
92
Core-To-Edge Fabric
94
By-14 Core-To-Edge Fabric
94
By-12 Core-To-Edge Fabric
95
Fabric Island
96
Planning a Fibre Channel Fabric Topology
97
Fabric Performance
97
Application I/O Profiles
98
I/O Requirements
98
ISL Oversubscription
99
Device Locality
100
Device Fan-Out Ratio
101
Device Locality
101
Performance Tuning
102
Device Fan-Out Ratio
102
Fabric Performance Tuning
103
Fabric Availability
104
Redundant Fabrics
105
Redundant Fabrics
106
Fabric Scalability
107
Obtaining Professional Services
107
Fabric Topology Design Considerations
107
Large Fabric Design Implications
107
FCP and FICON in a Single Fabric
108
Director or Switch Management
109
Port Numbering Versus Port Addressing
110
Director 2/64 Port Numbers and Logical Port Addresses
110
Management Limitations
111
Protocol Intermix Recommendations
112
Multiple Data Transmission Speeds in a Single Fabric
114
Physical Planning Considerations
115
Port Connectivity and Fiber-Optic Cabling
116
Port Requirements
116
Optical Transceivers
117
Cost Effectiveness
118
Data Transmission Distance
118
Device or Cable Restrictions
118
Extended-Distance Ports
119
High-Availability Considerations
119
Cables and Connectors
120
Cables
120
Director and Switch Connectors
121
Routing Fiber-Optic Cables
121
SFP Transceiver and LC Duplex Connector
121
HAFM Server, LAN, and Remote Access Support
122
HAFM Server
122
HAFM Server Connectivity
123
Connectivity Planning Considerations
124
Remote User Workstations
124
Typical Network Configuration (One Ethernet Connection)
126
Typical Network Configuration (Two Ethernet Connections)
127
SNMP Management Workstations
128
Web Browser Access
128
Inband Management Access (Optional)
129
Security Provisions
131
Password Protection
131
Types of User Rights
131
Name Server Zoning
132
Product Zoning
132
Benefits of Zoning
133
Configuring Zones
133
Joining Zoned Fabrics
135
Factors to Consider When Implementing Zoning
136
Server and Storage-Level Access Control
136
Obtaining Professional Services
137
Optional Features
138
Inband Management Console Access
139
FICON Management Server
139
Open Systems Management Server
139
Flexport Technology
140
Santegrity Binding
140
Enterprise Fabric Mode
141
Santegrity Binding Planning Considerations
142
Open Trunking
142
Configuration Planning Tasks
145
Task 1: Prepare a Site Plan
146
Physical Planning and Hardware Installation Tasks
148
Operational Setup Tasks
149
Task 2: Plan Fibre Channel Cable Routing
151
Task 3: Consider Interoperability with Fabric Elements and End Devices
152
Task 4: Plan Console Management Support
153
Task 5: Plan Ethernet Access
154
Task 6: Plan Network Addresses
155
Task 7: Plan SNMP Support (Optional)
156
Task 8: Plan E-Mail Notification (Optional)
157
Task 9: Establish Product and HAFM Server Security Measures
157
Task 10: Plan Phone Connections
158
Task 11: Diagram the Planned Configuration
158
Task 12: Assign Port Names and Nicknames
158
Rules for Port Names
159
Rules for Nicknames
159
Task 13: Complete the Planning Worksheet
159
Task 14: Plan AC Power
164
Task 15: Plan a Multi-Switch Fabric (Optional)
165
Task 16: Plan Zone Sets for Multiple Products (Optional)
166
Index
167
Advertisement
HP StorageWorks 64 - SAN Director Switch User Manual (146 pages)
embedded web server
Brand:
HP
| Category:
Software
| Size: 2.73 MB
Table of Contents
Embedded Web Server
1
Table of Contents
3
About this Guide
9
Overview
10
Intended Audience
10
Related Documentation
10
Conventions
11
Document Conventions
11
Text Symbols
12
Equipment Symbols
12
Rack Stability
13
Getting Help
14
HP Technical Support
14
HP Storage Website
14
HP Authorized Reseller
15
Introduction
17
Overview
17
Using EWS to Perform Tasks
17
Viewing the User Interface
19
Example Embedded Web Server Page for Edge Switch 2/24
19
Figures 1 Example Embedded Web Server Page for Edge Switch 2/24
19
Benefits
20
Key Terms
21
Fabric
21
Storage Area Network (SAN)
22
Zone (Zoning)
22
Zone Member
22
Zone Set
22
Suggested Reading
22
Where to Start
23
Starting EWS
23
Enter Network Password Dialog Box
24
Switch Tab View
24
Configuring the Product
25
Factory Default Values
26
Configuring Ports
26
Configure Ports Tab View
27
Configuring Product Identification
29
Configure Product Identification Tab View
29
Configuring Date and Time
31
Configure Date and Time Tab View
31
Configuring Operating Parameters
32
Configure Product Parameters Tab View
32
Configuring Fabric Parameters
35
Fabric Parameters Tab View
35
Configuring Network Information
38
Configuring Network Parameters Tab View
38
Network Information Message Box
39
Configuring SNMP
40
Configure SNMP Parameters Tab View
40
Enabling or Disabling the CLI
42
Disabling the CLI
42
Enabling or Disabling Host Control
43
Enabling OSMS Host Control
43
Zoning Tab View
44
Configuring User Rights
44
Configuring User Ids
44
User Rights Settings
46
User Rights Levels
46
Binding Ports to Devices
47
Configuring Port Binding
48
Configuring Open Trunking
49
Configuring Open Trunking
50
Installing Feature Keys
52
Feature Installation Tab View
53
Configuring Zones
55
Understanding Zoning
55
Controlling Access Across a Fabric
55
Zoning through a Single Fibre Channel Managed Product
56
Zoning through a Multiswitch Fabric
57
Controlling Access at the Switch
58
Controlling Access at the Server or Storage Device
58
Zoning Concepts
59
Naming Conventions for Zones and Zone Sets
60
Zones
60
Using Wwns
60
Using Port Numbers
61
Default Zone
62
Zone Sets
62
Active Zone Set
63
Merging Zoned Fabrics
63
Rules for Merging Zoned Fabrics
64
Merging Zones
64
Configuring, Adding, or Deleting Zones
65
Configuring Zones
66
Modify Zone Tab View
67
Configuring Zone Sets
69
Zone Set Tab View
69
Viewing Product and Fabric Data
71
Viewing Product Information
72
Viewing a Representation of the Product
72
Switch Tab View for an Edge Switch 2/24
72
State Definitions
73
Status Indicators
74
Viewing Port Properties
75
Port Properties Tab View
75
Viewing FRU Properties
79
FRU Properties Tab View
79
Viewing Unit Properties
80
Unit Properties Tab View
80
Viewing Operating Parameters for the Product
81
Operating Parameters Tab View
81
Viewing Fabric Information
82
Viewing Operating Parameters for a Fabric
83
Viewing Fabric Directors and Switches
83
Fabric Tab with Products Tab View
84
Parts of the Product Cell
85
Product Cell Information
85
Information on the Product Cell
85
Parts of the Product Graphic
86
Operating Status Symbols
87
Viewing Fabric Topology
88
Fabric Tab with Topology Tab View
88
Components of the Topology Page
89
Monitoring Products
91
Monitoring Ports
91
Port List
91
Port Operational States
92
Port List Tab View
92
Accessing Port Statistics
94
Troubleshooting Tip for Port Stats
94
Port Statistics Tab View
94
Parts of Statistics Tables
95
Traffic Transmit and Receive Statistics
95
Class 2 Statistics
96
Class 3 Statistics
96
Error Statistics
97
Open Trunking Statistics
98
Reviewing the Event Log
98
Log Tab View
98
Severity Levels
99
Error Event Code Categories
99
Clearing Event Log Entries
100
Clearing the System (Product) Error Light
100
Viewing Node List
100
Node List Tab View
100
Obtaining Product Information
103
Setting Product Beaconing on or off
104
Setting Product Online or Offline
105
Resetting Product Configuration to Default Values
106
Operating and Managing Products and Parts
103
Key Tasks
103
Performing Diagnostics on Ports
103
Resetting Ports
103
Setting Product Beaconing
103
Resetting Product to Default Values
106
Set Individual Port Beaconing on or off
107
Resetting Ports
109
Performing Diagnostics on Ports
110
Retrieving Maintenance Information
112
Obtaining Product Information
114
Upgrading Firmware
115
Activating (Installing) Optional Features
116
A Error Messages
117
Embedded Web Serve Messages
117
Index
139
HP StorageWorks 64 - SAN Director Switch Cli Reference Manual (160 pages)
CLI reference guide for director 2/64, edge switch 2/16, and edge switch 2/32
Brand:
HP
| Category:
Switch
| Size: 1.57 MB
Advertisement
Advertisement
Related Products
HP 615N - JetDirect Print Server
HP 625n - JetDirect Gigabit EN Print Server
HP 6200C
HP 620n - JetDirect - Print Server
HP 6530s - Notebook PC
HP 600N - JetDirect Print Server
HP 6200Cxi - ScanJet - Flatbed Scanner
HP Surestore 660ex - Optical Jukebox
HP 6715b - Notebook PC
HP Client Manager 6.1
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL