Determining Current Software Image Versions; Upgrading The Combined Ironware Application Image On Management Modules; Upgrading The Monitor Image On A Management Module - Dell PowerConnect B - MLXe 4 Hardware Installation Manual

Hardware installation guide
Table of Contents

Advertisement

Determining current software image versions

Before you upgrade your software, you should check the image versions currently installed to
determine which ones need to be upgraded. If there are images on your system that are not
compatible with R05.1.00 images, you will need to upgrade those images in addition to the basic
required images.
To display image version information, enter the show flash or show version command. Compare the
image versions to the compatible image version numbers in the table "Software images for
R05.1.00."
To see output examples of the show flash and show version commands, refer to "Displaying flash
information and "Displaying version information."
You should also check the installed images immediately after an upgrade to confirm that the
upgrade was successful.
You should also verify that you have enough available flash memory to complete your upgrade.
Refer to "Important upgrade memory requirements information."
Upgrading the combined IronWare Application Image on
management modules
1. Place the new software images on an accessible TFTP server, or on a flash card inserted in slot
2. Copy the new image from the TFTP server or the flash card to the flash memory on the
3. Verify that the new image has been successfully copied to the specified destination by entering
To upgrade other software images, refer to the appropriate upgrade section. When you have
completed your upgrade, you must reboot the management module. Refer to "Rebooting the
Management Module."

Upgrading the monitor image on a management module

To upgrade the monitor image on a management module, perform the following steps:
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
1 or 2 on the active management module.
management module by entering one of the following commands at the Privileged EXEC level
of the CLI:
copy tftp image <tftp_srvr> xm05100.bin primary | secondary
copy slot1 | slot2 flash <ip-addr> xm05100.bin primary | secondary
The primary option copies the files to the primary image on the management module. The
secondary option copies the files to the secondary image on the management module.
one of the following commands at the Privileged EXEC level of the CLI:
show flash (if the destination was code flash)
dir /<path-name>/ (if the destination was slot 1 or 2)
Check for the primary or secondary image and the date and time that it was placed in the
directory.
Software upgrade procedures
6