6
Displaying image versions
Performing a coherence check without a reload
Enter the reload-check command to perform a coherence check without performing a reload, as
shown in the following example:
PowerConnect# reload-check
Checking for coherence...
Warning: The new LP PBIF-8X10 FPGA will not be compatible with the new LP 3
application.
Warning: The new LP XPP-8X10 FPGA will not be compatible with the new LP 3
application.
Done.
PowerConnect#
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can't check LP for coherence
Error messages generated by the coherence check
The following error messages are generated if a coherence check fails:
Warning: Image coherence check skipped due to insufficient info: Invalid active LP
# flash images in Primary/Secondary.
Warning: Image coherence check skipped due to insufficient info: Invalid active MP
flash images in Primary/Secondary.
Warning: Image coherence ckeck skipped due to insufficient info: MP/LP not booting
from flash.
Warning: Image coherence check skipped due to failure to communiate with LP.
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can't check LP for coherence
Displaying image versions
The following sections describe how to display software image version information for
PowerConnect B-MLXe routers, using the show flash or show version commands.
Using the show flash command
You can display the images stored in flash memory using the show flash command.
NOTE
This example is for illustration only and may not reflect current image version information.
Output from the show flash command resembles this example.
PowerConnect# show flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
138
.
.
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01