1. Make sure the cable is securely connected to your PC or terminal and the console port or
2. Check the settings in your terminal emulation program. In addition to the session settings
When you see this prompt (MLXe-16#), you are connected to the system and can display module
status using the CLI. Enter the show module command at any CLI level.
MLXe-16# show module
M1 (upper): NetIron Mgmt Module
M2 (lower):
F0: NetIron Switch Fabric Module
S1:
S2:
S3:
S4: NetIron 4-Port 10Gig Module
S5: NetIron 4-Port 10Gig Module
S6: NetIron 4-Port 10Gig Module
S7:
S8:
Syntax: show module
The Status column shows the module status. The management module status can be one of the
following:
The switch fabric module status can be one of the following:
An interface module status can be one of the following:
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
Ethernet port.
listed in
"Attaching a PC or terminal to the console port or Ethernet port"
sure the terminal emulation session is running on the same serial port you attached to the
console port.
Module
ACTIVE – The module is currently the active management module.
STANDBY – The module is currently the standby management module.
COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.
ACTIVE – The module is up and running.
BAD – The management module cannot initialize the switch fabric module.
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
CARD_STATE_BOOT – The module is booting.
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.
CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
CARD_STATE_POWER_OFF – The module does not have power.
CARD_STATE_UP – The module is operating normally.
Verifying proper operation
Status
Ports Starting MAC
Active
Active
CARD_STATE_UP
4
000c.db80.0000
CARD_STATE_UP
4
000c.db80.0000
CARD_STATE_UP
4
000c.db80.0000
2
on page 68, make