Dell PowerConnect B - MLXe 4 Hardware Installation Manual page 61

Hardware installation guide
Table of Contents

Advertisement

NOTE
If you are installing a redundant management module, refer to the chapter titled "Using a Redundant
Management Module" in the PowerConnect B-MLXe Configuration Guide for information about how
the redundant module works, optional software configurations, and how to manage redundancy.
Before installing a module in the PowerConnect B-MLXe-8 router, have the following items
available:
DANGER
For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.
You can install modules while the router is powered on and running.
The router ships with slot blanks installed in all empty module slots. The slot blanks help ensure
proper airflow inside the router. You must remove the slot blank to install a module.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the router
with an uncovered slot, the system may overheat. Tighten the screws that secure the slot blanks
so that they remain in place when removing adjacent panels or modules.
Although the slot blanks differ in size, the procedure for removing them is identical. You will need a
flat-blade screwdriver to perform this task.
Slot blank removal steps
Follow these steps to remove a slot blank.
1. Loosen the screws on either end of the slot blank by hand or with a flat-blade screwdriver.
2. Pull the slot blank out of the router, and store it in a safe place for future use.
CAUTION
If you are hot-swapping a module, allow a minimum of two seconds after a module (or power
supply or fan tray) has been removed before inserting a module in the same slot.
Module installation steps
Follow this procedure to install a module in the router.
1. If you are installing a module in a slot which may have been configured for a different module
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
A large flat-blade screwdriver.
An ESD wrist strap with a plug for connection to the ESD connector on the router.
type, remove the old configuration information by following these steps.
a. Use the show running-config command in config mode to determine the current
configuration of the slot.
PowerConnect(config)# show running-config
Current configuration:
Installing a PowerConnect B-MLXe-8 router
2
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerconnect b - mlxe 8

Table of Contents