Dell PowerConnect B - MLXe 4 Hardware Installation Manual page 128

Hardware installation guide
Table of Contents

Advertisement

5
Managing interface modules
Specifying an immediate boot from management module flash memory
To specify an immediate boot from the primary image on the management module for the interface
module installed in slot 1, enter the following command at the Privileged EXEC level of the CLI.
PowerConnect# lp boot system mp primary 1
Syntax: lp boot system mp primary | secondary <slot-number>
Specifying an immediate boot from flash memory on the interface module
To specify an immediate boot from the primary image in flash memory on the interface module
installed in slot 1, enter the following command at the Privileged EXEC level of the CLI.
PowerConnect# lp boot system flash primary 1
Syntax: lp boot system flash [primary | secondary] <slot-number>
Specifying an immediate boot from a TFTP server
To specify an immediate boot for the interface module installed in slot 1 from a TFTP server, enter
the following command at the Privileged EXEC level of the CLI.
PowerConnect# lp boot system tftp 123.123.123.123 primary 1
Syntax: lp boot system tftp <ip-address> <filename> <slot-number>
Specifying an immediate interactive boot
To specify an immediate interactive boot for the interface module installed in slot 1, enter the
following command at the Privileged EXEC level of the CLI.
PowerConnect# lp boot system interactive 1
Syntax: lp boot system interactive <slot-number>
116
The <slot-number> parameter specifies the device slot number that contains the interface
module that will undergo an immediate boot. You can specify 1 – 4 for 4-slot devices, 1 – 8 for
8-slot devices, or 1 – 16 for 16-slot devices.
The primary and secondary keywords specify the primary or secondary software image in flash
memory on the management module.
The <slot-number> parameter specifies the device slot number that contains the interface
module that will undergo an immediate boot.You can specify 1 – 4 for 4-slot devices, 1 – 8 for
8-slot devices, or 1 – 16 for 16-slot devices.
The primary and secondary keywords specify the primary or secondary image in the interface
module flash memory.
The <slot-number> parameter specifies the slot number that contains the interface module
that will undergo an immediate boot.You can specify 1 – 4 for 4-slot devices, 1 – 8 for 8-slot
devices, or 1 – 16 for 16-slot devices.
The <ip-address> parameter specifies the IP address of the TFTP server from which the
interface module will be booted.
The <filename> parameter specifies the name of the image from which to boot the interface
module.
The <slot-number> parameter specifies the slot number that contains the interface module
that will undergo an immediate boot. You can specify 1 – 4 for 4-slot devices, 1 – 8 for 8-slot
devices, or 1 – 16 for 16-slot devices.