Installing a PowerConnect B-MLXe-4 router
The PowerConnect B-MLXe-4 router ships with slot blanks installed in all empty module slots. The
slot blanks help ensure proper airflow inside the router. You must remove the slot blank to install a
module into a slot.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you operate the
router with an uncovered slot, the system may overheat. Tighten the screws that secure the slot
blanks so that they remain in place when removing adjacent panels or modules.
Although the slot blanks differ in size, the procedure for removing them is identical. You will need a
flat-blade screwdriver to remove slot blanks.
Slot blank removal steps
Follow these steps to remove a slot blank.
1. Loosen the screws on either end of the slot blank by hand or with a flat-blade screwdriver.
2. Pull the slot blank out of the router, and store it in a safe place for future use.
CAUTION
If you are hot-swapping a module, allow a minimum of two seconds after a module (or power
supply or fan tray) has been removed before inserting a module in the same slot.
Module installation steps
Follow these steps to install a module.
1. If you are installing a module in a slot which may have been configured for a different module
2. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on
3. Remove the module from the packaging.
36
type, remove the old configuration information by following these steps.
a. Use the show running-config command in config mode to determine the current
configuration of the slot.
PowerConnect(config)# show running-config
Current configuration:
!
ver V5.1.0aT163
module 1 ni-mlx-24-port-1g-copper
!
This example shows that slot 1 has already been configured for a 24-port 1 Gbps copper
interface module.
b. Enter the no module <slot-number> <module-type> command to remove the configuration
from slot 1, using the information shown as a result of the show running-config command.
PowerConnect(config)# no module 1 ni-mlx-24-port-1g-copper
This example removes the existing configuration from slot 1, leaving it ready for a new
module.
the front of the chassis.