Installing a Tape Drive
To install a tape drive:
CAUTION: To prevent damage to equipment or loss of information, make sure
that the server is powered down, all cables are disconnected from the server,
and the power cord is disconnected from the grounded (earthed) AC outlet
before removing the access panel.
1. Remove the access panel by following the steps in the section applicable
to your tower or rack server at the beginning of this chapter.
2. Install guide screws on the sides of the drive.
3. To configure the device, set the SCSI device ID. You must manually set
the SCSI device ID on each device to a unique value in the range of
0 through 6 for each SCSI bus. Refer to the documentation provided
with the drive for instructions on setting the SCSI device ID.
4. Slide the drive into the drive bay until it clicks into place.
Figure 3-15. Installing a tape drive (DLT)
NOTE: The interior of the server may look different depending on the model purchased.
IMPORTANT: Compaq recommends installing the tape drive on a separate SCSI cable to
avoid a decrease in performance of other SCSI devices.
Hardware Options Installation 3-17