Related
Documentation
Use of Status LEDs to Monitor the High Availability States of Line Modules
Related
Documentation
Monitoring the Redundancy Status of Line Modules in a Specific Slot
Purpose
Action
host1#show redundancy line-card slot 3
Line Card
---------
automatic reverting is off
High
last
Availability
activation
slot
State
type
----
--------
---------
3
disabled
Criteria Preventing High Availability from being Active
-------------------------------------------------------
slot
---
----------------------------------------------------
3
Running configuration is safe for High Availability?
Copyright © 2010, Juniper Networks, Inc.
impacted by the improvements made to the compatible protocols and applications. In
a scaled topology, simultaneous switchover of all the line modules in a chassis is
supported. The operations of line modules that no not support stateful switchover is also
not impacted in any manner, owing to the changes made to HA-safe applications.
Application Support for Stateful Line Module Switchover on page 79
System Operations When Stateful Line Module Switchover Is Enabled on page 74
You can determine the redundancy state of line modules and SRP modules by examining
their status LEDs. The LED on the line module denotes the state of the line module. In
addition, if you issue the show version command, the state field for the slot that contains
the redundant line module indicates standby. The following are the functions of the LEDs
for the different states of the line modules in a high availability pair:
OK LED—This LED is turned off while the secondary line module is switching over
ONLINE LED—There is no difference in the method of illumination of this LED, regardless
of whether line module high availability is enabled.
REDUNDANT LED—This LED is turned on for the secondary line module and is not
illuminated for the primary line module.
Monitoring the Redundancy Status of Line Modules in a Specific Slot on page 95
Monitoring the Redundancy History of Line Modules in a Specific Slot on page 97
Display the supported redundancy modes as well as other status relating to high
availability for a line module installed in a particular slot.
To display the redundancy information of a line module in a particular slot.
hardware
lockout
role
config
-------
------
cold
---
---
criterion
Chapter 4: Managing Stateful Line Module Switchover
backed
up
sparing
by
for
revert
slot
slot
------
-------
------
---
---
met
---
No
at
---
95
Need help?
Do you have a question about the JUNOSE SOFTWARE FOR E SERIES 11.3.X - SERVICE AVAILABILITY CONFIGURATION GUIDE 2010-10-08 and is the answer not in the manual?