Configuring Snmpv3 From An Nms; Configuring Snmpv3 From The Cli - Cisco WS-C4003 - Catalyst 4000 Chassis Switch Software Configuration Manual

Software guide
Table of Contents

Advertisement

Configuring SNMPv3 from an NMS

Configuring SNMPv3 from an NMS
To configure SNMP from an Network Management System (NMS), refer to your NMS documentation
(also see the
The switch supports up to 20 trap receivers through the RMON2 trap destination table. Configure the
RMON2 trap destination table from the NMS.

Configuring SNMPv3 from the CLI

This section provides very basic SNMP v3 configuration information. For detailed information on the
Note
SNMP commands supported by the Catalyst enterprise LAN switches, refer to the Command
Reference—Catalyst 4000 Family, Catalyst 2948G, and Catalyst 2980G Switches.
To configure SNMPv3 from the command-line interface (CLI), perform this task in privileged mode:
Task
Step 1
Set the SNMP-Server EngineID
name for the local SNMP engine.
Step 2
Configure the MIB views.
Step 3
Set the access rights for a group
with a certain security model in
different security levels.
Step 4
Specify the target addresses for
notifications.
Step 5
Set the snmpTargetAddrEntry in
the target address table.
Step 6
Set the SNMP parameters used to
generate a message to a target.
Step 7
Configure a new user.
Step 8
Relate a user to a group using a
specified security model.
Software Configuration Guide—Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4
23-10
"Using CiscoWorks2000" section on page
Command
set snmp engineid engineid
set snmp view [-hex] {viewname} {subtree} [mask] [included |
excluded] [volatile | nonvolatile]
set snmp access [-hex] {groupname} {security-model v3}
{noauthentication | authentication | privacy} [read [-hex]
{readview}] [write [-hex] {writeview}] [notify [-hex]
{notifyview}] [context [-hex] {contextname} [exact | prefix]]
[volatile | nonvolatile]
set snmp notify [-hex] {notifyname} tag [-hex] {notifytag}
[trap | inform] [volatile | nonvolatile]
set snmp targetaddr [-hex] {addrname} param [-hex]
{paramsname} {ipaddr} [udpport {port}] [timeout {value}]
[retries {value}] [volatile | nonvolatile] [taglist {[-hex] tag}
[[-hex] tag]]
set snmp targetparams [-hex] {paramsname} user [-hex]
{username} {security-model v3} {message-processing v3}
{noauthentication | authentication | privacy} [volatile |
nonvolatile]
set snmp user [-hex] {username} [remote {engineid}]
[{authentication [md5 | sha] {authpassword}] [privacy
{privpassword}] [volatile | nonvolatile]
set snmp group [-hex] {groupname} user [-hex] {username}
{security-model v1 | v2 | v3} [volatile | nonvolatile]
Chapter 23
23-13).
Configuring SNMP
78-12647-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 4000 seriesCatalyst 2948gCatalyst 2980g

Table of Contents