Cross-Zoning - GE Simon 60-875 Installation Instructions Manual

Hide thumbs Also See for Simon 60-875:
Table of Contents

Advertisement

28 PIR motion sensor, sound sensor or pressure mat.‡ No reports
29 Auxiliary: Freeze Sensors
32 PIR motion sensor or sound sensor‡ No reports
34 Carbon Monoxide Alarm
35 Entry/Exit Delay Interior PIR Motion
36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if
tripped. RF Thermostat. DTIM (tamper only).
37 Light Switch Control: X10 Modules turn either on or off when a door is opened.
No reports.
38 Auxiliary: Water Sensors.
* This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
§ This type is required for UL-listed residential fire alarm applications.
‡ This type has not been investigated by UL.
# See "Cross Zoning" section on page 72
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is not active, otherwise alarm sounds after programmed
entry delay time)
Note
Cross-Zoning is not recom-
mended for exit/entry zones.
Each zone has the ability to
individually protect the
intended area. (e.g. motion
detector patterns overlap).
72
Sensor Group Characteristics
Name/Application

Cross-Zoning

Cross-Zone (Two-Trip) refers to two different Group 18 sensors that must be tripped
within two minutes of each other to report an alarm to the central station. The diagram
in Figure 14 shows the path of a person walking from the kitchen to the living room.
When the person is detected walking through the kitchen, the motion sensor in the
kitchen is tripped, sounding a local alarm. If motion is detected by the living room
motion sensor within two minutes, an alarm report will be sent to the central station.
D i n i n g
K i t c h e n
R o o m
L i v i n g
R o o m
D e t e c t i o n P a t h / K i t c h e n M o t i o n S e n s o r
D e t e c t i o n P a t h / L i v i n g R o o m
M o t i o n S e n s o r
P a t h o f P e r s o n W a l k i n g
Figure 14. Cross-Zone Diagram
Siren Type
Silent
Trouble
Beeps
Silent
Emergency
Intrusion
Intrusion
Silent
Trouble
Beeps
B e d r o o m
B e d r o o m
B e d r o o m
M o t i o n S e n s o r
Active
in
Levels
I
No Yes
01234
I
Yes Yes
01234
I
No
No
01234
I
Yes Yes
01234
S
No Yes
234
I
Yes Yes
1234
I
No Yes
01234
I
Yes Yes
01234
Simon Security System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simon 60-910Simon 600-1012

Table of Contents