Performing Scheduling Operations (cont'd)
Quit ?
1 = yes 0 = no
0
NOTE: Because the time windows are shared among all partitions, it
is important to make sure that changing a time window does not
adversely affect other programmed Time-Driven events.

Time-Driven Event Programming

The following schedules can be used to activate outputs, bypass zones,
arm/disarm the system, etc. based on a time schedule. Up to 20 events
can be programmed for the system. Time windows must first be
defined in order to be used to trigger events.
After entering Scheduling Menu Mode, press 0 until the "Timed
Events ?" prompt appears.
Timed Events ?
1 yes
0 = no
0
TIMED EVENT # ?
01-20, 00=QUIT
01
When the entry is completed, the "TIME
WINDOW #?" prompt is displayed again.
Enter the next time window number to be
programmed and repeat the procedure; or enter
00 and press [*] to quit programming time
windows. When you enter 00*, the keypad
displays the following:
Press 0 at the "Quit ?" prompt to return to the
main menu choices and continue programming.
Press 1 to quit Scheduling Menu Mode.
Press 1 to program timed events.
Enter the timed event number to be
programmed (01-20).
Press [
.
]
The system prompts you to enter the desired
action to be taken.