The actions that can be programmed to automatically activate at set
times are: relay commands, arm/disarm commands, zone bypassing
commands, open/close access conditions, and access control commands.
NOTES:
The time-driven events described here are also used to control other
functions in your system. Your installer may have already
programmed some time-driven events to control system functions. If
some time-driven events have already been programmed, make
certain that the first Timed Event # you use is higher than the last
number already programmed, or you will overwrite your existing
time-driven events.
Action codes 60 (AP Exit Only), 66 (AP Group Exit Only), or 72 (AP
Partition Exit Only) disable the entry reader at the access point.
The reader will remain disabled until a command is received (via a
keypad command or event) to protect the access point.
At the end of a time window controlling an access point, the access
point will revert to the protect mode.
Preparing a Time-Driven Events Worksheet
Fill out the Time-Driven Events Worksheet (located near the end of
this manual) using the steps outlined below.
As an aid to understanding the procedures for filling out the Time-
Driven Events Worksheet, assume that we want to enable access groups
1 and 2 from 08:00 AM to 05:00 PM (set via time window 01) on
Monday through Friday. As you perform the following steps, examples
are provided for filling out the worksheet to obtain this condition.
1. Enter the Action No. listed in Table 1: Action Codes for the
action desired.
Example: Enter Action No. 77 for Access Group Enable.
Performing Scheduling Operations (cont'd)
– 41 –