User Commands (cont'd)
ACTION
ACTION
NO.
NAME
Bypass Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass commands. If 3 (During) is
selected for auto-bypassing, the system bypasses the zone(s) specified on a particular zone list at the beginning of the
window and unbypasses the zone(s) at the end of the window. If it is selected for auto unbypassing, the system
removes the bypass of the zone(s) at the beginning of the window and restores the bypass at the end of the window.
30
Bypass Zn
List
31
Unbyps Zn
List
Open/Close Windows
Activation time 3 (During) is the only valid choice for these commands. When using Enable Open Window, Enable
Close Window, and Enable Access Window, the window is active for the partitions selected by the specifier except as
follows:
When an Event/Action occurs that would disable a window (partition not selected), the window for the partition is only
disabled if it is not currently enabled by a timed method (e.g., O/C schedule, Time-Driven Event, Access Schedule).
When a timed window (e.g., O/C schedule, Time-Driven Event, Access Schedule) occurs that would disable a window
(partition not selected), the window for the partition is only disabled if it is not currently enabled by an Event/Action.
40
En Open
Wind
41
En Close
Wind
42
En Access
Wind
50
Off-Normal
Reminder
Access Related Actions
All access-related actions are active during the time window and you are not presented with a prompt requesting an
activation time.
55
AP Grant
56
AP Grant/O
57
AP Protect
58
AP Bypass
59
AP Lock
60
AP Exit Only
– 14 –
Table 1: Action Codes (cont'd)
ACTION
ACTION
SPECIFIER
DESCRIPTION
Zone list #
Auto bypass zone list – Automatically bypass the zone list
indicated by the specifier
Zone list #
Auto unbypass zone list – Automatically unbypass the zone list
indicated by the specifier
Partition(s)
Enable Opening Window by partition – Enable the opening
window for the partition indicated by the specifier
Partition(s)
Enable Closing Window by partition – Enable the closing window
for the partition indicated by the specifier
Access
Enable Access Window for access group – Enable the access
Group
window for the access group indicated by the specifier (enables
user arming or disarming)
None
Off-Normal Reminder – Starts local keypad beeping if fire off-
normal condition exists
Access Point
Access Point Grant – Grant access at access point indicated by
#
specifier
Access Point
Access Point Grant with Override – Grant access with override
#
at access point indicated by specifier
Access Point
Access Point Protect – Protect access point indicated by
#
specifier
Access Point
Access Point Bypass – Bypass access point indicated by
#
specifier
Access Point
Access Point Lock – Lock access point indicated by specifier
#
Access Point
Access Point Exit Only – Put access point indicated by specifier
#
in Exit Only mode