Intel® Server Chassis SC5300 5U Kit TPS
10. Environmental Limits
10.1 System Office Environment
Parameter
Operating Temperature
Non-Operating
Temperature
Non-Operating Humidity
Acoustic noise
Operating Shock
Package Shock
ESD
10.2 System Environmental Testing
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-05.
These tests shall include:
•
Temperature Operating and Non-Operating
•
Humidity Non-Operating
•
Packaged Shock
•
Packaged and Unpackaged Vibration
•
AC Voltage, Frequency, and Source Interrupt
•
AC Surge
•
Acoustics
•
Electrostatic Discharge (ESD)
•
EMC Radiated Investigation
Revision 1.31
Table 48. System Office Environment Summary
o
o
+5
C to +35
C with the maximum rate of change not to exceed
o
10
C per hour.
o
o
-40
C to +70
95%, non-condensing @ 30
55 dBA in a typical office ambient temperature (18-25
No errors with a half sine wave shock of 2G (with 11-millisecond
duration)
Operational after a free fall, 18 – 24 inch depending on the weight.
15kV per the Intel Environmental Test Specification
Limits
C
o
C
Environmental Limits
o
C)
89