Intel
LB440GX 2U Rack Server Chassis TPS Rev 1.0
12 Environmental Limits
12.1
System Office Environment
Parameter
Operating Temperature
Non-Operating
Temperature
Non-Operating Humidity
Acoustic noise
Operating Shock
Package Shock
ESD
12.2
System Environmental Testing
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-03. These
tests shall include:
Temperature Operating and Non-Operating
Humidity Non-Operating
Packaged and Unpackaged Shock
Packaged and Unpackaged Vibration
AC Voltage, Freq. & Source Interrupt
AC Surge
Acoustics
ESD
EMC Radiated Investigation
Limits
+5 o C to +35 o C with the maximum rate of change not to
exceed 10 o C per hour.
-40 o C to +70 o C
95%, non-condensing @ 30 o C
< 45 dBA in an idle state at typical office ambient
temperature (65-75F)
No errors with a half sine wave shock of 2G (with 11
millisecond duration).
Operational after a 24 inch free fall, although cosmetic
damage may be present
20kV per Intel Environmental test specification
Table 10. System Office Environment Summary
20