Installation and operating manual
9.3.4 Visual inspection
During the visual inspection, check all components for mechanical damage and leaks. Replace damaged
components immediately.
9.3.5 Leak test
A leak test is only possible if the product is completely filled with water.
1. Pour tap water into the product through the vent until water comes out from the outlet.
2. Check all hose and other connections for leaks.
Error or fault pattern
Leaky hose connection
Bayonet catch leaking
End cap leaking
Measure
•
Tighten the hose clamp.
•
Replace hardened hose and respective hose
clamps.
•
Check the fit of the seal and correct if necessary.
•
Check the seal for damage and replace if
necessary.
•
Tighten the bayonet fitting.
•
Check the seal for damage and replace if
necessary.
•
Check the fit of the seal and correct if necessary.
•
Check the seal for damage and replace if
necessary.
•
Tighten the end cap.