14. Place the end cap on the filter cartridge and turn
it clockwise all the way.
15. Remove the cover from the pressure relief
chamber and remove the activated carbon mat
from the vent of the pressure relief chamber.
0 Check the activated carbon insert to see if
it is very dirty (e.g., mold, oil saturation) and
replace it if necessary.
16. Fill the product with tap water via the vent.
0 Stop filling it as soon as water comes out
from the condensate outlet.
17. Insert the activated carbon mat into the vent of
the pressure relief chamber and place the cover
on the pressure relief chamber.
18. Slowly open the condensate feed.
19. Check all hoses and connections for leaks (see
section "9.3.5 Leak test" on page 53).
0 Retighten if necessary
20. Slowly pressurize the system.