4. Technical data
4.1 Operating parameters
Parameters
Relative ambient air humidity
Maximum operating altitude above sea level
Maximum operating pressure at condensate inlet
Minimum / maximum operating temperature, fluids 
and environment
Maximum condensate flow rate
Condensate inlet port
Condensate outlet port
Media
Maximum operating weight
Maximum oil concentration at condensate drain
*2
port
4.2 Storage parameters
Parameters
Minimum / maximum temperature
Relative ambient air humidity
Empty weight
1
Will continue to operate up to a maximum of 3000 m (3280.84 yd) above sea level
2
Provided that the reference conditions published by DIBt (Deutsches Institut für Bautechnik) are adhered to
20 | 68
*1
*2
Installation and operating manual
QWIK-PURE
®
≤10 ... 80 %, without condensation
2000 m
2187.23 yd
16 bar(g)
230 psi(g)
+5 ... +50 °C
+41 ... +122 °F
12.7 l/h
3.36 gal/h
3 x G1/2", male,
1 x G1", male,
Barbed hose fitting:
1 x 25 mm (0.98 in), male ,
1 x 13 mm (0.52 in), male
25 mm (0.98 in), male
Barbed hose fitting
Compressor condensate, oil-contaminated
50 kg
110.2 lbs
10 mg/l
10 ppm
QWIK-PURE
®
+5 °C ... +50 °C
+33.8 °F ... +122 °F
≤10 ... 80 %, without condensation
13.5 kg
29.8 lbs
CS 400