Download Print this page

Beko QWIK-PURE CS 400 Installation And Operating Manual page 39

Hide thumbs Also See for QWIK-PURE CS 400:

Advertisement

Installation and operating manual
8. Operation
Operating personnel (see section "2.3 Target group and personnel" on page 8)
8.1 Warning notices
NOTICE
8.2 Working during operation
1.
The product has been installed and connected to the condensate collection line and the drain.
2.
The product must have been successfully set up.
Personnel
Reduced filter cartridge performance
When the clean water tank's ventilation opening is closed, the draining water
will produce a negative pressure in the clean water tank. This negative pressure
will result in the condensate being sucked through the filter cartridges in an 
uncontrolled manner. This uncontrolled flow will reduce the performance of the 
filter cartridges. 
Keep the clean water tank's ventilation opening open.
Preparation work
QWIK-PURE
CS
®
39 | 68