9.3.1 Turbidity test of the purified condensate
Tools
No tool necessary
Figure
NOTICE
42 | 68
Prerequisites
No material necessary
High condensate turbidity
If the condensate at the condensate outlet has a high degree of turbidity, clean the
device – please refer to section "9.3.3 Cleaning" on page 48.
Material
Description
1. Remove the reference turbidity tube from the
holder and fill it with a water sample from the 
service valve.
2. Compare the sample with the reference turbidity
on the lower half of the reference turbidity tube.
The sample is clearer than the reference turbidity:
0 The product is working properly.
The sample is equally or more turbid than the
reference turbidity
0 Replace the filter cartridges immediately.
3. Document the result of the turbidity test.