Installation and operating manual
9.3.2 Replace filter cartridges
Tools
No tool necessary
1.
Have the required number of new filter cartridges ready to go next to the product.
2.
Remove the plugs from the new filter cartridges' packaging and set them down close to the 
product.
Figure
Prerequisites
Material
Filter cartridges
Can for flushing
Approx. 40 l of tap water
Can for collecting the flushing 
water
Preparation work
Description / explanation
1. Shut off the condensate feed and divert the 
condensate into a separate container.
2. Connect the service valve on the clean water
tank to a collecting container and open the
service valve.
0 Close the service valve the moment that
Protective equipment
To be worn at all times:
condensate stops coming out.