APPENDIX С -
ERROR MESSAGES
DIAGNOSTIC MESSAGE LIST (CONT'D)
TEMPERATURE ERROR
This message appears if the temperature circuit returns an error or if the temperature calibration data
is in error. Check the temperature probe and its connections. A broken temperature probe wire is the
most common cause of this error. See the troubleshooting section.
VCF DOMAIN ERROR
This message indicates that the calculated temperature falls outside the allowable range for the
current compensation parameter. Verify that the correct product compensation type (see PRODUCT
SET-UP) is being used.
PULSER FAILURE
This message appears if the number of pulser faults exceeds the allowable amount. The number of
allowable faults is determined by an equation and cannot be changed. A maximum of 5 times the
number of pulses required for the least significant displayed digit OR 0.1% of the pulses generated
for the current delivery are allowed. Pulser faults generally occur in high vibration environments or
when the flow rate is highly throttled. Liquid Controls is not responsible for pulser failures caused by
excessive system vibrations. See the troubleshooting section.
METER CALIB ERROR
A product that has not been calibrated has been selected for delivery. Select a valid calibrated
product.
PRESET STOP
This message appears if the delivery has stopped due to a GROSS or NET PRESET amount being
reached. This is not an error condition.
NO FLOW STOP ERROR
This message appears if the NO-FLOW TIMER has expired, causing the current delivery to be
terminated. This is not an error condition. Entering "0" for this parameter in the GENERAL SET-UP
menu can turn off the NO-FLOW TIMER, however, this results in a system that is less secure.
STOP REQUESTED
This message appears when a STOP command has been sent to the LCR-II system to pause the
delivery. STOP can be activated from the Selector Switch, Lap Pad, or a Terminal. This is not an error
condition.
DELIVERY END REQST
This message appears when a PRINT command has been sent to the LCR-II system to terminate
a delivery. PRINT can be activated from the Selector Switch, Lap Pad, or a Terminal. This is not an
error condition
POWER FAIL ERROR
This message appears when a delivery was ended due to a loss of input voltage. Check the power
supply and wiring to the LCR-II. Check the in-line fuse. See the troubleshooting section.
PRESET ERROR
This message appears when a flash memory error is detected during a delivery when accessing any
of the fields used by PRESETS. This includes GROSS PRESET amount, NET PRESET amount, S1
CLOSE VALUE, remaining PRESET amounts, the PRESET type, or PRESET ALLOWED fields.
TERMINAL NOT CONNECTED
This message appears when a Terminal or Lap Pad is disconnected during a delivery. Check the
cables and connectors for broken wires and loose connections.
CHECK PRINTER AND CABLE
This message appears when the printer is not responding. This can be the result of a faulty data
cable, power cable, or LCR-II circuit board failure. The most common cause is that a ticket is not in
place in the printer. The Epson Slip printers have a built in photo eye to detect if a ticket is in position.
DATA ACCESS ERROR
This message appears when a flash memory error occurs.