Delivery & Selections Menu (cont'd)
SHIFT PRINT POSITION (PRODUCT ^/TOTALIZER) (CONT')
A shift ticket is printed when the Selector Switch is placed in the SHIFT PRINT Position for more than 2 seconds and
a printer is loaded with paper and available to print the ticket. (NOTE: If the Selector Switch is turned to SHIFT PRINT
and then out of SHIFT PRINT in less than 2 seconds, a Diagnostic/Calibration Information ticket is printed). Delivery
Total is the initial display. The display will update every 15.625 ms.
Press SELECT to advance to Product Number.
Product Number Display
Prod 1
The current active Product Number is displayed. If a delivery is not active, the digit will be flashing,
indicating that it can be changed. If the display is NOT flashing, it cannot be changed. Press INCREASE to
scroll through the options. These options are Prod 1, Prod 2, Prod 3, or Prod 4, depending on the number
of products programmed during calibration. When the desired option has been chosen, press SELECT to
advance.
Shift Totalizer Display (1 of 2)
H12 34 5
This displays the five most significant digits of the GROSS or NET Shift totalizer. Press INCREASE to return
to the Product Number display. Press SELECT to advance.
Shift Totalizer Display (2 of 2)
L6789.0
This displays the five least significant digits of the GROSS or NET Shift totalizer. The shift totalizer is a
combination of these two screens. The total in this example is "543,216,789.0" units. Press INCREASE to
return to the previous totalizer display. Press SELECT to return to Delivery Total.
Printing Diagnostic/Calibration Tickets
If a delivery was terminated due to a pulser failure, temperature probe failure or other fault, the last line on the delivery
ticket will read, "'FAULT: PRINT DIAGNOSTICS TICKET*".
A Diagnostic Ticket is printed when the Selector Switch is turned to the SHIFT PRINT Position for less than two
seconds. This ticket contains the same information found on the calibration ticket that prints when the Calibration
Mode is exited, but does not increment the calibration number or require a Weights & Measures seal to be broken.
This allows the operator to spot check the calibration of the register and/or diagnose problems with the unit. The ticket
will show any problems on the last line to assist in troubleshooting the problem.