MEMORY AND SCAN OPERATION
5
E Programmed scan operation
© Select VFO mode.
@ Select the desired operating mode.
¢The operating mode can also be changed while scan-
ning.
@ Set [SQL] open or closed.
«See aoe a left for squelch condition.
@ Select 2, then push [(F-1):(CF4] to start the scan.
° Decimal polit blinks while scanning.
@®When the scan detects a signal, the scan turns
OFF,
pauses
or ignores
it depending
on the
resume setting and the squelch condition.
e During scan [TS] can be used only when resume is ON.
© To cancel the scan push [(F-1) ZH].
E Memory scan operation
@ Select memory mode.
@ Close the squelch with [SQL].
@ Select 2, then push [(F-1)=CH] to start the scan.
e Decimal point blinks while scanning.
@ When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
© To cancel the scan push [(F-1) iH].
E Select memory scan operation
© Select memory mode.
@ Close the squelch with [SQL].
@ Select = 2, then push [(F-1)=:h] to start the mem-
ory scan.
e Decimal point blinks while scanning.
@ Push [(F-2)E1.] to change the memory scan to
select memory scan.
¢Push [(F-2)=ElL.] for 2 sec. to clear all select memory
channels.
© When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
© To cancel the scan push [(F-1)
H].
E Priority watch
© Select VFO mode, then set a frequency.
@ Close the squelch with [SQL].
@ Set the desired memory channel as the watching
channel.
@ Select 3", then push [(F-2)F'F I] to start the watch.
e Decimal point blinks while scanning.
@ When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
© To cancel the scan push [(F-2)F F I].
USB
Mees OF
uf
Select
VFO mode
s3579
2
4 ues
ae
ory
fcH
S2
SCH
PŘI
UW-M
then push [(F-) CH]
Note: If the same frequencies are programmed into
the scan edge memory channels P1 and P2, pro-
grammed scan does not start.
Select
rane
la|
memory mode
then push [(F-1) SCH]
Note: Two or more memory channels must be pro-
grammed for memory scan to start.
Select
memory mode
Push [(F-1)=(C HH], then [(F-2)EL].
Note: Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.
USB
Ho la m p ng ; ri
Select
eas
VFO mode
si
357
9
2
40
dB
VFOA
S2 SCH PRT
Select watching
channel
Push [(F-2)PR I].
Note: The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.