Chapter 23 Classifier

Figure 48 Classifier

The following table describes the labels in this screen.

Table 41 Classifier

LABEL
Active
Name
Packet
Format
Layer 2
122
DESCRIPTION
Select this option to enable this rule.
Enter a descriptive name for this rule for identifying purposes.
Specify the format of the packet. Choices are All, 802.3 tagged, 802.3 untagged,
Ethernet II tagged and Ethernet II untagged.
A value of 802.3 indicates that the packets are formatted according to the IEEE 802.3
standards.
A value of Ethernet II indicates that the packets are formatted according to RFC 894,
Ethernet II encapsulation.
Specify the fields below to configure a layer 2 classifier.