Chapter 10 — Troubleshooting
Display Messages and LED Indications (continued)
92
Error/Event
RtW
1 This is only applicable for printers equipped with an EasyLAN
interface.
2 A printer that is equipped with an EasyLAN interface, but is not
connected to a network, will have a blinking RtW. To avoid this,
the user can set "IP SELECTION" to "MANUAL" and "IP
ADDRESS" to "0.0.0.0". This will indicate that the user does not
regard the lack of network connection as an error.
3 No trap can be sent when this error/event occurs.
4 This error indicates that the printer has not received an IP address.
It is only applicable for printers with IP SELECTION set to
DHCP and/or BOOTP.
5 In the Direct Protocol, the user can enable error handling for
specific errors using the ERROR statement. When errors added to
the built-in error handling occur, this event will be set. The text
included in the snmp trap is the standard text corresponding to the
error.
6 If an error occurs in the Fingerprint immediate mode, for example
"out of paper" when the print key is pressed, this event will be set.
7 If an application is started but does not execute, the RtW will
blink. This will occur for example if there is a syntax error in the
loaded program file.
• This is useful when a printer has an AUTOEXEC.BAT file
(startup file) that is supposed to run automatically.
8 When execution is stopped with user break (SHIFT + PAUSE) or
due to a runtime error, the RtW shall be off. It will be set to on if
the user changes mode to Direct Protocol or runs an application.
• If, however, the application program handles the user break (ON
BREAK) or the runtime error (ON ERROR GOTO), the RtW
will not be affected. In this case, it is up to the application to set
the status.
9 At most, but not all, printer crashes the console is reset. This will
turn off the RtW.
10 If the printhead temperature raises above 100°C, error 1088
occurs.
• In Fingerprint, printing will be aborted. Resuming printing after
the printhead has cooled off to 85°C must be handled by the
application program.
• In the Direct Protocol, the printing is paused but will be
automatically resumed when the printhead has cooled off to 85°C.
Meanwhile, the printer is able to receive instructions
EasyCoder PM4i Printer User's Guide (Fingerprint Version)
Error
No.
Comment

Hide quick links: