Pointing Devices; Special Error Codes; Device Names; Test Names - HP xw4100 Service And Technical Reference Manual

Hp xw4100: reference guide
Hide thumbs Also See for xw4100:
Table of Contents

Advertisement

pointing devices

error code
8601-xx
8602-xx

5.5.3 special error codes

This section includes the error codes for the following devices:
SCSI hard drives
SCSI tape drives
SCSI PD-CD drives
All CD-ROM drives
The SCSI error codes consist of three components, AABB-CC, where
AA = Device Name
BB = Test Name
CC = Error Code
For example, a diagnostic error code of 6523-05 indicates that the diagnostics program was
testing the hard drive random-read function and received a seek failure. The device is faulty and
must be replaced.

device names

65XX-XX
66XX-XX
67XX-XX

test names

XX00-XX
XX05-XX
XX06-XX
XX08-XX
XX09-XX
XX23-XX
XX28-XX
hp workstation xw4100 service and technical reference guide
description
Mouse test failed.
Interface test failed.
Hard Drive
CD-ROM Drive and PD-CD Drive
Tape Drive
ID
Read
SA/Media
Controller
Media erase
Random read
Media load/unload
system diagnostics and troubleshooting
recommended action
The following steps apply to 8601-xx through
8602-xx:
1. Replace with a working mouse and
retest.
2. Replace the system board and retest.
5–17