4.15. Engine shut down

Normally the cooling down of the engine during descenting and taxiing will be sufficient to allow the engine to be
shut off as soon as the ULL aircraft has stopped.
At increased operating temperatures cool down the engine at least minimum of 2 minutes.
1.
Engine instruments - check values
2.
Avionics - switch "OFF"
3.
Toggle switches - switch "OFF"
4.
Throttle - CLOSE
5.
Magneto A and B switches - switch "OFF"
6.
Wait for engine stop.
7.
Master switch - switch "OFF"

4.16. Leaving ULL aircraft

1.
Magneto A and B switches - switched "OFF" (check)
2.
Master switch and toggle switches – switched "OFF" (check)
3.
Emergency Parachute System - LOCK
4.
Fuel cocks - CLOSE
5.
Canopy – CLOSE, lock
6.
Chock or tie down ULL aircraft, Cover canopy