1.
Move primary landing gear control lever to "DOWN" position (bottom position) – if not already in "DOWN" position
2.
Re-circ the landing gear circuit breaker and wait 30 seconds
3.
If three red lights or combination of green and red are shinning (for each wheel must shine at least one light) turn
the emergency landing gear control lever until three greens are shinning or the mechanical indicator is in correct
position
4.
Proceed with normal landing (see Art. 4.13.1)
After the flight is necessary to check of the landing gear system by a technical staff.
If at least one red light does NOT shine (neither the green) and at the same time they area in orther then:
- Minumum one locking hook is locked
- Do NOT use emergency extending of landing gear
- Proceed with a Belly landing (aacording to Art. 3.3.4)

3.3.8. Loss of engine power in flight

1.
Establish the glide, at airspeed, at airspeed 100-110 km/h
2.
Switch the fuel cock to other fuel tank
3.
Altitude - in accordance with actual altitude:
- try to restart engine according to Art. 3.3.9
- if unsuccessful, perform an Emergency landing to terrain (according to Art. 3.3.2)

3.3.9. In flight engine restart

1.
All unnecessary equipment - switch "OFF"
2.
Continue according to Art. 4.2 Starting the engine
Be prepared for engine failure and Emergency landing to terrain (see Art. 3.3.2).

3.3.10. Engine fire - on ground

1.
Fuel cock - CLOSE
2.
Brakes - use parking brake
3.
Magneto A and B switches – switch "OFF"
4.
Master switch - switch "OFF"