American Dynamics EDVR Installation And Operation Manual page 20

American dynamics edvr: operation guide
Hide thumbs Also See for EDVR:
Table of Contents

Advertisement

EDVR Installation and Operation Guide
16-Channel EDVR Alarm I/O Connections (also see notes after tables)
Pin#
1
GROUND
2
DISK FULL (OUTPUT)
3
ALARM2 OUT (OUTPUT)
4
RECORD IN (INPUT)
5
ALARM1 IN (INPUT)
6
ALARM3 IN (INPUT)
7
ALARM5 IN (INPUT)
8
ALARM7 IN (INPUT)
9
ALARM9 IN (INPUT)
10
ALARM11 IN (INPUT)
11
ALARM13 IN (INPUT)
12
ALARM15 IN (INPUT)
13
No connection
Notes
GROUND: Ground Contact.
DISK FULL (OUTPUT): This is a disk full output trigger. Connect to external devices such as buzzers
or lights. (
ALARM OUT (OUTPUT): This is an alarm output trigger. Connect to external devices such as
buzzers or lights. (
RECORD IN (INPUT): This pin connects to a record trigger device for starting a record.
(
ALARM RESET (INPUT): This pin connects to an alarm-clear device for clearing an alarm.
(
ALARM IN (INPUT): This is an alarm input (for each channel) that can be programmed in the menu
system to Normally Open or Normally Closed. (
Attaching an External Device to an EDVR
The EDVR provides facilities to report 3 auxiliary alarm outputs for associated equipment – such as the spotlight,
buzzer, or blinker alarm – and 16 alarm inputs for the 16CH EDVR version (9 for the 9CH; 4 for the 4CH).
The alarm outputs are related to the alarm indication.
The input alarms are reported to the management system and are activated by a closed or open loop condition.
Connect an alarm out, alarm input, and a peripheral device as shown in the following diagram.
Alarm Input: An input connection to the EDVR that triggers the EDVR unit to active (buzzer and
message display) if one of the alarm input links (the sensor of each channel) is activated (that is, turned
ON).
Alarm Output: An output connection to the warning devices that triggers the warning unit to turn on an
alarm with sound or light. When combining a warning device to the EDVR, connect the Pin#1 GROUND
and the Pin#3/15/16 ALARM OUTPUT.
10
Pin Assignment
5V
)
0V(Active)
5V
)
0V(Active)
5V
)
0V(Active)
5V
)
0V(Active)
Pin#
Pin Assignment
14
RESERVED
15
ALARM1 OUT (OUTPUT)
16
ALARM3 OUT (OUTPUT)
17
ALARM RESET (INPUT)
18
ALARM2 IN (INPUT)
19
ALARM4IN (INPUT)
20
ALARM6 IN (INPUT)
21
ALARM8 IN (INPUT)
22
ALARM10 IN (INPUT)
23
ALARM12 IN (INPUT)
24
ALARM14 IN (INPUT)
25
ALARM16 IN (INPUT)
5V
)
0V(Active)
EDVR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents