Operation
Switching charac-
teristic
5.6.7.2
The binary data output of the outputs can be set in this menu point. For binary data output, you can choose
between the network (UDP), RS232 or USB interfaces.
A maximum of 500 Hz can be transmitted via the network (RJ45) and USB and a maximum of 380 Hz via the
RS232 interface.
Fields with gray
background re-
quire a selection.
Fields with dark
Val-
border require
ue
entry of a value.
colorSENSOR CFO
Choose switching
characteristic
Number of out-
puts
CFO250
Go to the menu Settings > Outputs > Binary data output.
Determines the switching behavior of the switching outputs. The fol-
lowing interfaces are available:
OFF
NPN
Outputs OUT switch to ground (GND) when color
group is detected (activated)
PNP
Outputs OUT switch according to supply voltage
(V
) when color group is detected (activated)
+
PUSH-PULL
Push-pull outputs OUT switch to supply voltage
(V
) when color group is detected (activated) and
+
to ground (GND) when not detected
Value