Judgment Result Output

Overall judgment result

The ZFX-C outputs the OR signal indicating the overall judgment result. The following items can be specified
whether or not to be included in the overall judgment result. The user can select whether a signal is output
when the overall judgment result is OK or NG.
Setting Reflection of Individual Results
- Position correction item
- Measurement item
- Calculation (variable) result
- Calculation (judgment) result
- Logging monitor warning

Individual judgment result

The judgment results based on the expressions that were set in the [Add func/Calculation/Judge/judge 0 to 31]
are output to DO0 to DO15. The user can select whether a signal is output when the judgment result is OK or
NG. The default setting is for a signal to be output when the judgment result is NG.
Calculation p.115
1st time
Expression 15
2nd time
Expression 31
Up to 32 individual judgment results are output. No data is output when the judgment is not set in the
Expression.
ZFX-C User's Manual
p.119
Judgment result for expression 0 to 15
DO15
DO14 DO13 DO12 DO11 DO10 DO9 DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
Judgment result for expression 16 to 31
DO15 DO14 DO13 DO12 DO11 DO10 DO9 DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
Expression 0
Expression 16
165
Signal I/O