Note
The display range of the graph's horizontal and vertical axes can be changed in the ADJ mode.
Adjusting Logging Monitor Conditions p.131
Erasing Measurement Values
This function allows you to erase (reset) accumulated data without having to turn the Controller OFF.
MENU mode - [Setup] - [Add func] - [Logging monitor] - [Log0/1/2] - [Erase]

File Format

The format of files saved on SD card are as follows:
Data is delimited by a comma ","
<max. value>,<min. value>,<average value>,<standard deviation>,<measurement count>,<NG count>,<NG rate>,<warning count>
<max. value>,<min. value>,<average value>,<standard deviation>,<measurement count>,<NG count>,<NG rate>,<warning count>
<max. value>,<min. value>,<average value>,<standard deviation>,<measurement count>,<NG count>,<NG rate>,<warning count>
0,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>,<time>
1,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>,<time>
2,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>,<time>
. . .
. . .
. . .
. . .
99,<log 0 measurement value>,,,<time>
0,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>
1,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>
2,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>
. . .
. . .
. . .
9999,<log 0 measurement value>,<log 1 measurement value>,<log 2 measurement value>
*1: When a warning is inserted consecutively for even one of logs 0 to 2, the measurement values are logged.
*2: Commas are aligned where logs are not set.
Example: 1,<measurement value>,,,<time>
Note
Difference between NG count and warning count
The "NG count" is the number of times that the measurement value exceeds or falls below the warning level.
The "warning count" is the number of times that the measurement value exceeded or fell below the warning level
continuously for the number of times set for the warning count or more in the setup conditions.
NG count
0
1
Warning count
0
0
105
Warning value
100
(upper limit)
Measurement value 80
40
Warning value
(lower limit)
Saving/Loading Data p.150
ZFX-C User's Manual
2
2
3
4
5
6
6
0
0
0
0
1
2
2
111
104 108
101
99
77
22
Log 0 statistical data
Log 1 statistical data
Log 2 statistical data
latest warning
1 previous warning
2 previous warning
Measurement result
at warning *1,2
(max. 100 results)
99 previous warning
latest
1 previous
Measurement result
2 previous
on graph *2
(10,000 latest results)
99 previous
Additional Functions
121