Region settings
This function sets the region to be registered as the model and the region to search for the model.
MENU mode - [Setup] - [Item] - [Region]
Item
Description
Register model
This function registers the image pattern to find as the model.
Reference model
The image that is registered as the model can be referenced.
Search region
Set the region in which to search for the model.
Threshold
This function sets the judgment conditions.
MENU mode - [Setup] - [Item] - [Limits]
Setup Item
Description
Correlation
Sets the range of the correlation to be judged as OK.
Range: 0 to 100
Position XY
Sets the range of movement in the X- and Y- axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999
(When calibration is OFF, the range of movement for positions X and Y are 0 to 640 and 0
to 480, respectively.)
Index No.
Sets the range of index Nos. to be judged as OK.
Range: 0 to 63
Image adjustment (if necessary)
The following items can be changed and set to the image of the measurement target.
MENU mode - [Setup] - [Item] - [Img Adj]
Item
Description
Select camera
Color filter
Filtering
BGS level
ZFX-C User's Manual
Setting the Region p.213
For details, see "Image Adjustment". p.99