Possible output results
The following values can be output when expressions are set.
Item
Description
Judgment result
The judgment result is output. (0:OK, -1:NG, -2: not measured)
Edge width
The measured edge width is output. (0 to 9999.999)
Edge position 1/2
The X, Y coordinates of the edge position are output.
(-9999.999 to 9999.999)
The start point side of the region becomes Position X1/Y1, and the
end point side becomes Position X2/Y2.
Reference edge width
The edge width when the measurement region is set is output.
(0 to 9999.999)
Reference edge position
The X, Y coordinates of the edge position when the measurement
1/2
region is set are output. (-9999.999 to 9999.999)
Width difference
The width difference obtained by "measurement value - reference
value" is output. (-9999.999 to 9999.999)
Position difference 1/2
The difference obtained by "measurement position - reference
position" is output. (-9999.999 to 9999.999)
Position Difference p.50
ZFX-C User's Manual
Important
Message
Judge (JG)
Width (WD)
Position
X1, Y1, X2, Y2
(X1, Y1, X2, Y2)
Reference width (SW)
Reference
X1, Y1, X2, Y2
(SX1, SY1, SX2, SY2)
Width dif. (DW)
Position dif.
X1, Y1, X2, Y2
(DX1, DY1, DX2, DY2)
Setting Measurement Items
79