ENABLE reverse
Set whether or not to reverse the ON/OFF state of the ENABLE signal.
MENU mode - [System] - [Comm] - [ENABLE output] - [Reverse]
Setting value
Description
OFF
The ON/OFF state of the ENABLE signal is not reversed. (default value)
ON
The ON/OFF state of the ENABLE signal is reversed. The ENABLE signal turns ON dur-
ing processing by the ZFX. The ENABLE signal can be used as a signal for indicating that
the ZFX-C is executing processing.

Ethernet Communication

Set the communications specifications for performing communications with external devices on an Ethernet
connection.
MENU mode - [System] - [Comm] - [Ethernet]
Setting value
Description
Connection
Sets whether to enable or disable Ethernet communications.
ON: Ethernet communications is enabled. (default value)
OFF: Ethernet communications is disabled. This shortens the measurement time.
IP address
Sets the same address (excluding the rightmost address) as the PC that the ZFX-C is
connected to.
Set a unique address as the rightmost address. Do not set the same address twice in the
network. (0.0.0.0 to 255.255.255.255, default value: 192.168.0.250)
Subnet mask
Sets the same subnet mask as the PC that the ZFX-C is connected to. (0.0.0.0 to
255.255.255.255, default value: 255.255.255.0)
Default gateway
Sets the IP address of the default gateway.
Important
• Port number is fixed to 23.
• Before connecting to an existing LAN, consult with the network administrator to confirm the network settings. If
wrong settings are set, the ZFX-C and other devices on the network might no longer function properly.
• The ZFX-C cannot be controlled simultaneously from multiple PCs on the network.
• The network state sometimes causes a delay in data communications with the ZFX-C. If a fast response is required,
we recommend performing data communications over a parallel I/O interface.
• The firewall functions of the PC that the ZFX-C is connected to might disturb data communications with the ZFX-C.
In this case, disable the firewall on the PC.
ZFX-C User's Manual