ENABLE Signal Output

The following three output pattern can be specified for ENABLE signal.
Outputs when an
ENABLE
image is input
Outputs when
measurement processing
ENABLE
is completed
Outputs when
display is completed
ENABLE

OR Signal Output

The following two output pattern can be specified for the OR signal.
Level output
Output of the overall judgment is retained until output of the next overall judgment.
OFF
ENABLE
ON
OFF
OR
ON
One-shot output
The OR signal is remained to be ON during the output time set in [System/Comm/OR output/Output time] when
[One-shot] is set in [System/Comm/OR output/Output mode].
OFF
ENABLE
ON
OFF
OR
ON
ZFX-C User's Manual
Image input
Measurement
OFF
ON
Measurement time
OFF
ON
Measurement time
OFF
ON
Measurement time
Starts measurement results output.
Display
Timing Charts
173