Omron SJDE-ANA-OY Manual page 143

Junma sjde-**ana-oy series servo c
Table of Contents

Advertisement

Alarm
Alarm Name
Display
A.100
Overcurrent
A.280
Emergency
Stop
A.400
Overvoltage
A.410
Undervolt-
age
Situation at Alarm
Occurrence
Occurred when the
The SERVOPACK is faulty.
power supply was
turned ON or while
the servomotor was
The servomotor is faulty.
running.
Occurred during
The emergency stop signal
execution of
is not connected.
MECHATROLINK-II
command SV_ON.
Occurred while the
The emergency stop signal
servomotor was
was input.
running.
Malfunction occurred on the
emergency stop signal
Occurred when the
The AC power supply volt-
power supply was
age is 290 V or more.
turned ON.
The SERVOPACK is faulty.
Occurred during
AC power supply voltage
operation.
changed excessively.
The servomotor speed is
high and the load moment
of inertia is excessively
large (insufficient regenera-
tive power processing
capacity).
The SERVOPACK is faulty.
Occurred when the
The power supply was
power supply was
turned ON again before the
turned ON.
SERVOPACK power supply
was turned OFF.
A temporary power failure
occurred.
The SERVOPACK is faulty.
8.3 Alarm/Warning Display and Troubleshooting
Cause
141
Corrective Actions
• Replace the SERVOPACK.
• Contact your Omron
Yaskawa representative.
Check the resistance between
lines of the servomotor, and
replace the servomotor if any
unbalance is found.
Wire correctly according to the
descriptions in 3.7.3 Emer-
gency Stop Signal Input.
Refer to 4.7.5 Operation
Sequence When E-STP Sig-
nal is Input.
Check and then correct the
wiring.
Keep the AC power supply
voltage to the specified range.
• Replace the SERVOPACK.
• Contact your Omron
Yaskawa representative.
Keep the AC power supply
voltage within the specified
range.
• Reconsider the load and
operation conditions.
• Install a regenerative unit.
• Replace the SERVOPACK.
• Contact your Omron
Yaskawa representative.
Turn ON the power supply
again after the REF LED goes
out.
Reset the alarm, and then
restart the operation.
• Replace the SERVOPACK.
• Contact your Omron
Yaskawa representative.
(cont'd)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents