Omron SJDE-ANA-OY Manual page 100

Junma sjde-**ana-oy series servo c
Table of Contents

Advertisement

4.5 Command Data Field
Positioning completion (PSET)
Indicates the completion of positioning.
D7
0
Other than the status 1.
1
Output completion (DEN = 1) and the feedback position (APOS) are within the
positioning complete range.
The positioning complete width can be set in the following parameter.
The setting will be immediately written in the SERVOPACK.
Parameter
Name
No.
Pn522
Positioning
complete
width
Positioning complete
range
Machine coordinate
system APOS
Target position
Status
Data Size
4 bytes
Within range.
Positioning complete
width (Pn522)
Min.
Max.
Set Value
Set Value
0
1073741824
98
Units
Factory
Setting
Reference
10
unit