Auxiliary Area Allocations by Address
Address
Name
Words
Bits
A400
All
Error code
A401
A401.00 Other Fatal
Error Flag
A401.06 FALS Error
Flag
(fatal error)
A401.08 Cycle Time
Too Long Flag
(fatal error)
A401.09 Program Error
Flag
(fatal error)
556
Function
When a non-fatal error (user-defined
FALS(006) or system error) or a fatal
error (user-defined FALS(007) or
system error) occurs, the 4-digit
hexadecimal error code is written to
this word. When two or more errors
occur simultaneously, the highest
error code will be recorded.
ON when a fatal error that is not
defined for A401.01 to A401.15
occurs. Detailed information is output
to the bits of A314.
There are no errors that affect this
flag at this time. This flag is reserved
by the system.
ON when a fatal error is generated
by the FALS(006) instruction. The
CPU Unit will stop operating and the
ERR/ALM indicator will light.
The corresponding error code will be
written to A400. Error codes C101 to
C2FF correspond to FALS numbers
001 to 511.
This flag will be turned OFF when
the FALS errors are cleared.
ON if the cycle time exceeds the
maximum cycle time set in the PLC
Setup (the cycle time monitoring
time). CPU Unit operation will stop
and the ERR/ALM indicator on the
front of the CPU Unit will light.
This flag will be turned OFF when
the error is cleared.
ON when program contents are
incorrect.
CPU Unit operation will stop and the
ERR/ALM indicator on the front of
the CPU Unit will light. The task num-
ber where the error occurred will be
stored in A294 and the program
address will be stored in A298 and
A299.
The type of program error that
occurred will be stored in A295.08 to
A295.15. Refer to the description of
A295 for more details on program
errors.
This flag will be turned OFF when
the error is cleared.
Settings
Status
Status
after
at star-
mode
change
---
Cleared
Cleared
OFF: No
Cleared
Cleared
other fatal
error
ON: Other
fatal error
ON:
Cleared
Cleared
FALS(006)
executed
OFF:
FALS(006)
not executed
OFF: Cycle
Cleared
Cleared
time under
max.
ON: Cycle
time over
max.
ON: Error
Cleared
Cleared
OFF: No error
Appendix D
Write
Related
timing
flags, set-
tup
tings
Refreshed
---
when error
occurs.
Refreshed
A314
when error
occurs.
Refreshed
A400
when error
occurs.
Refreshed
PLC
when the
Setup
cycle time
(Cycle
exceeds
time moni-
maximum.
toring
time)
Refreshed
A294,
when error
A295,
occurs.
A298 and
A299