◆ Alarm and Error Displays

Faults
Table 6.9
gives an overview of possible fault codes. As conditions such as overvoltage can trip both a fault and an alarm,
it is important to distinguish between faults and alarms in order to find the right corrective action.
When the drive detects a fault, the ALM indicator LEDs lights and the fault code appears on the display. The drive fault
contact MA-MB-MC will be triggered. If the ALM LED blinks and the code appearing on the operator screen is flashes,
then an alarm has been detected. See
Digital Operator Display
LED Operator
LCD Operator
boL
Braking Transistor Overload Fault
bUS
Option Communication Error
MEMOBUS/Modbus Communication
CE
Error
CF
Control Fault
,
CPF00, CPF01
Control Circuit Error
<1>
CPF02
A/D Conversion Error
CPF03
Control Board Connection Error
CPF06
EEPROM Memory Data Error
,
CPF07,
Terminal Board Connection Error
CPF08
,
CPF20, CPF21
Control Circuit Error
<1>
CPF22
Hybrid IC Error
CPF23
Control Board Connection Error
CPF24
Drive Unit Signal Fault
to
CPF26 to CPF34 Control Circuit Error
Excessive Speed Deviation (for Control
dEv
Mode with PG)
dv1
Z Pulse Fall Detection
dv2
Z Pulse Noise Fault Detection
dv3
Inversion Detection
dv4
Inversion Prevention Detection
dWFL
DriveWorksEZ Fault
E5
SI-T3 Watchdog Timer Error
EF0
Option Card External Fault
to
EF1 to EF8
External Fault (input terminal S1 to S8)
Err
EEPROM Write Error
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Minor Faults and Alarms on page 302
Table 6.9 Fault Displays (1)
Name
Page
LED Operator
306
306
306
306
306
306
307
307
307
307
307
307
307
307
308
308
308
308
308
308
308
309
309
309
6.3 Drive Alarms, Faults, and Errors
for a list of alarm codes.
Digital Operator Display
LCD Operator
FAn
Internal Fan Fault
FbH
Excessive PID Feedback
FbL
PID Feedback Loss
GF
Ground Fault
LF
Output Phase Loss
LF2
Current Imbalance
nSE
Node Setup Error
oC
Overcurrent
oFA00
Option Card Connection Error (CN5-A)
oFA01
Option Card Fault (CN5-A)
to
oFA03 to oFA06
Option Card Error (CN5-A)
,
oFA10, oFA11
Option Card Error (CN5-A)
to
oFA12 to oFA17
Option Card Connection Error (CN5-A)
to
oFA30 to oFA43
Option Card Connection Error (CN5-A)
oFb00
Option Card Connection Error (CN5-B)
oFb01
Option Card Fault (CN5-B)
oFb02
Option Card Fault (CN5-B)
,
oFb03, oFb11
Option Card Error (CN5-B)
to
oFb12 to oFb17
Option Card Connection Error (CN5-B)
to
oFb30 to oFb43
Option Card Connection Error (CN5-B)
oFC00
Option Card Connection Error (CN5-C)
oFC01
Option Card Fault (CN5-C)
oFC02
Option Card Fault (CN5-C)
Name
Page
309
309
310
310
310
310
310
311
311
311
311
311
311
311
312
312
312
312
6
312
312
312
312
312
301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents