2.
Place the fan connector covered by the tube as shown in the drawings below.
Figure 7.22
3.
Make sure that the protective tube does not stick out beyond the fan guard.
Cooling Fan Wiring: 2A0250, 2A0312 and 4A0208
1.
Position the protective tube so that the fan connector sits in the center of the protective tube.
2.
Place the connector for fan B2 before the B1 connector and guide the lead wire for fan B2 so that it is held in
place by the cable hook.
Figure 7.23
Fan B1
3.
Make sure that the protective tube does not stick out beyond the fan guard.
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
2A0169, 2A0211, 4A0139
Fan B1
Connector for fan B1
Figure 7.22 Cooling Fan Wiring: 2A0169, 2A0211, 4A0139 and 4A0165
Protective tube
Fan B2
Figure 7.23 Cooling Fan Wiring: 2A0250, 2A0312 and 4A0208
7.4 Cooling Fan and Circulation Fan
4A0165
Fan B2
Connector for fan B2
YEG
Cable hook
Connector for fan B2
Connector for fan B1
YEG
YEG
361
7