100 Technical data
ACS180-04...
-055A-2
3-phase U n = 440 ... 480 V
-01A8-4
-02A6-4
-03A3-4
-04A0-4
-05A6-4
-07A2-4
-09A4-4
-12A6-4
-17A0-4
-25A0-4
-033A-4
-038A-4
-045A-4
-050A-4
1) 15 hp at 208...230 V input. 20 hp at 240 V input.

Definitions

The heavy duty ratings are valid at a surrounding air temperature of 50 °C (122 °F)
and the light duty ratings are valid at a surrounding air temperature of 40 °C
(104 °F) with the default drive switching frequency of 4 kHz (parameter 97.01), and
with an installation altitude below 1000 m (3281 ft).
U
Nominal supply voltage. For input voltage range U1, refer to
n
power network specification (page
I
Nominal input current with typical motor power P
1
input current, for dimensioning cables and fuses.
I
Maximum output current. Available for two seconds at start.
max
Input
Input
cur-
with
Max.
rent
choke
current
I 1
I 1
I max
A
A
59.6
55
79.2
1.9
1.3
2.2
2.4
1.6
3.3
3.5
2.1
4.3
4.6
2.8
5.9
6.9
3.8
7.2
9.2
5
10.3
6.7
14.8
11
16.9
20.3
14
22.7
26.6
21
30.6
33.9
27
41.3
34
57.6
46.9
40
68.4
46.9
42
Output ratings
Light-duty use
I Ld
P Ld
A
A
hp
50.2
15/20
1.6
0.75
2.1
1
3
1.5
3.5
2
4.8
3
10
6
3
13
7.6
5
11
7.5
14
10
21
15
45
27
20
34
25
40
30
81
42
30
129).
Heavy-duty use
I Hd
P Hd
A
hp
1)
44
15
1.1
0.5
1.6
0.75
2.1
1
3
1.5
3.5
2
4.8
3
6.3
3
7.6
5
11
7.5
14
10
21
15
27
20
34
25
42
30
. Continuous rms
n
Frame
size
R4
R0
R0
R0
R1
R1
R1
R1
R2
R2
R3
R3
R4
R4
R4
Electrical