Control Connection Data - ABB ACS180-04S-03A7-1 Hardware Manual

Table of Contents

Advertisement

Frame
m
R3
40
R4
30
1) Category C1 with conducted emissions only. Radiated emissions are not compatible when measured
with the standard emission measurement setup and must be measured on cabinet and machine
installations for each case.
Note:
Radiated emissions are according to C2 with single phase ACS180-04S...-1
drives. For ACS180-04S...-4 drives, use a metal enclosure to fulfill radiated
emissions C2/C1 limits with an external EMC filter.
External EMC filter must be used together with ACS180-04S-... drives.
For ACS180-04N... drives, the maximum motor cable lengths are according to
the motor cable length table. The EMC category for these drives is C4.
For ACS180-04S-...-2 drives, the EMC category is C4. In order to achieve higher
EMC category, must use external EMC filters.

Control connection data

Analog inputs (AI1,
AI2)
Analog output (AO)
Auxiliary voltage out-
put (+24V)
Maximum motor cable length, 4 kHz
1)
Class 1
ft
131
98
Voltage signal, single-
ended
Current signal, single-
ended
Inaccuracy
Potentiometer refer-
ence value
Current output mode
Voltage output mode
Inaccuracy
As output
Class 2
m
ft
40
131
30
98
0 ... 10 V DC (10% overrange, 11 V DC max.)
R in = 38 kohm
0 ... 20 mA (10% overrange, 22 mA max.)
R in = 205 ohm
≤ 1.0%, of full scale
10 V DC ±1%, max. load current 10 mA
0 ... 20 mA (10% overrange, 22 mA max.) into
maximum 500 ohm load
0 ... 10 V DC (10% overrange, 11 V DC max.)
into 200 kohm minimum load (resistive)
≤ 1.5%, of full scale
+24 V DC ±10%, max. 100 mA
Technical data 133
Class 3
m
ft
40
131
30
98

Advertisement

Table of Contents
loading

Table of Contents