Supermicro X13DEG-PVC User Manual page 70

Table of Contents

Advertisement

Super X13DEG-PVC User's Manual
UID LED
The unit identifier (UID) LED connection is located on Pin 3 of JF1.
Fail LED (Information LED for OH/FF/PF)
The Fail LED (Information LED for OH/Fan Fail/PWR Fail) connection is located on Pin 4 of
JF1. The LED provides warnings of overheating, power failure, or fan failure. Refer to the
table below for more information.
Status
Solid red (on)
Blinking red (1 Hz)
Blinking red (0.25 Hz)
Blinking red (10 Hz) (FP red LED)
Solid blue
Blinking blue (1 Hz)
BIOS/BMC blinking blue (10 Hz)
Red Info LED blinking (10 Hz) and
MB UID LED blue blinking (10 Hz)
JF1
1
Power Button
2
Reset/UID Button
3
UID LED_N
4
Fail LED_N (OH/FF/PF)
5
LAN-2 Activity LED
6
LAN-1 Activity LED (Aggregate all LAN)
7
HDD Acitivity LED
8
Standby LED_N
Power/RoT LED_N
9
10
P3V3_STBY
11
Ground
12
I2C Data
13
I2C Clock
14
Ground
Power Fail LED_P
15
16
P5V_USB
P5V_USB
17
18
P5V_USB
19
Power Fail LED_N
20
Ground
Fail LED (Information LED) (OH/Fan Fail/PWR Fail)
LED States
Description
An overheat condition has occurred.
Fan failure: check for an inoperative fan.
Power failure: check for a non-operational power supply
CPLD recovery mode error(s)
UID has been activated locally. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Local UID has been activated locally on. Use this function to identify a unit that
might be in need of service.
BIOS/BMC: recovery and/or update in progress
CPLD: recovery and/or update in progress
1
2
70
1. UID LED Indicator
2. Fail LED (Information LED
for OH/FF/PF)

Advertisement

Table of Contents
loading

Table of Contents