Industrial Ethernet Protocol Indication - Renesas R-IN32M3 User Manual

Hide thumbs Also See for R-IN32M3:
Table of Contents

Advertisement

R-IN32M3 Module

Industrial Ethernet Protocol Indication

5.3
Each Ethernet port has a RJ45 female connector with two indicator LEDs. The green LED
indicates the link status and the yellow LED lights up in response to network activity.
For complete industrial Ethernet conformance, adding two bi-color (red/green) LEDs is
recommended for the target device. In addition, the recommended method for controlling
each LED is defined in each communications standard. Therefore, the host CPU that
processed the data via the R-IN32M3 Module needs to control multiple LEDs.
Major protocol status conditions are listed in the following Table 5.1.
Table 5.1 State Indication
Industrial
Standard
PROFINET
Note 1
EtherNet/IP
Note 2
Note 1
PROFINET Diagnosis Guideline V1.4 Chapter 6.7 Signaling recommended an additional (third)
maintenance LED
Note 2
The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP
R19UH0111ED0100 Rev.1.00
June 30, 2020
Ethernet
State
LED1
System
failure
Module (MS) Green/
Color
State
LED2
Red
Bus failure
Network (NS)
Red
5.
Guideline
Color
Red
Green/
Red
Page 24 of 41