Field Service Ver. 1.1 May 2011
13.4.6

ADF MAIN REGIST

A. Use
• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-
ing the scanning start position in the main scanning direction (1-side) when using the
Automatic Document Feeder.
• When the original glass is replaced.
• When a new Auto Document Feeder Unit is mounted
NOTE
After the [CIS SUB ZOOM] adjustments have been performed
After the [ADF SUB ZOOM] adjustments have been performed
• Adjust the amount that widths A and B in the copy of the test pattern1 so that the follow-
ing specification is met.
• 0 ± 2.0 mm
B. Procedure
• The default setting is 0%.
-1.5 (-1.5 mm) ~ "0.0 (0.0 mm)" ~ +5.0 (+1.5 mm); Step: 0.5 mm
1. Print the test pattern1.
See P.155
2. Enter the [ADJUST] menu in the service mode.
3. Select [ADF MAIN REGIST], and press the Select key.
4. Place test pattern 1 in the ADF with its printed surface up.
5. Select [TEST COPY] and press the Select key to make a test copy.
NOTE
The test pattern1 should be positioned vertically.
Use A4 or Letter paper loaded into tray1 to make the test copy.
6. Check the amount that widths A and B in the copy of the test pattern are shifted. If the
shift is out of specification, adjust it according to the following procedure.
7. Select [ADJUST], and press the Select key
8. Using the
key, change the setting value and then press the Select key.
/
9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy
again and check it.
<Adjustment instructions>
If the width of A is less than the width of B..... Increase the setting.
If the width of B is less than the width of A..... Decrease the setting.
13. SERVICE MODE
B
A
4139F3C546DA