Field Service Ver. 1.1 May 2011
[1]
9. To reinstall, reverse the order of removal.
7.3.33
IDC sensor (IDC)
1. Remove the toner cartridge (C,M,Y,K).
See P.8
2. Remove the waste toner bottle.
See P.14
3. Remove the imaging unit (C,M,Y,K).
See P.11
4. Remove the exit cover.
See P.44
5. Remove the transfer belt unit.
See P.16
[2]
[1]
[2]
A0VDF2C064DA
[1]
A2YFF2C022DA
A2YFF2C113DA
7. OTHER MAINTENANCE ITEM
8. Disconnect the connector [1], and
remove the temperature/humidity
sensor [2].
6. Hold the both handles [1] and raise
the guide [2].
7. Raise the guide [1] further and
remove it.
NOTE
• Do not jerk off the sensor holder, to
which a harness is connected.
91